9170, 9171, 9172, & 9173 Metrology Well Calibrators

Fluke Calibration 9170, 9171, 9172 and 9173 Metrology Wells
Fluke Calibration 9170, 9171, 9172 and 9173 Metrology Wells
9171 Metrology Well
9173 Metrology Well well insert
Fluke Calibration 9170, 9171, 9172 and 9173 Metrology Wells
Fluke Calibration 9170, 9171, 9172 and 9173 Metrology Wells
9171 Metrology Well
9173 Metrology Well well insert
Request a quote
  • Highlights
  • Description
  • Specifications
  • Models and Accessories
  • Knowledge and Information

Accurate enough for lab use, and rugged and portable enough to take anywhere

  • Best-performing industrial heat sources (accuracy, stability, uniformity) in the world
  • Immersion depth to 203 mm (8 in)
  • Optional ITS-90 reference input reads PRTs to ±0.006 °C
  • Temperature range from –45 °C to 700 °C

Every once in a while, a new product comes around that changes the rules. It happened when we introduced handheld dry-wells. It happened when we introduced Micro-Baths. Now we’ve combined bath-level performance with dry-well functionality and legitimate reference thermometry to create Metrology Wells.

With groundbreaking new proprietary electronics from Fluke Calibration's (patents pending), Metrology Wells let you bring lab-quality performance into whatever field environment you might work in. New analog and digital control techniques provide stability as good as ±0.005 °C. And with dual-zone control, axial (or “vertical") uniformity is as good as ±0.02 °C over a 60 mm (2.36 in) zone. (That’s 60 mm!) Such performance doesn’t exist anywhere else outside of fluid baths.

In short, there are six critical components of performance in an industrial heat source (which the European metrology community explains, for example, in the document EA-10/13): calibrated display accuracy, stability, axial (vertical) uniformity, radial (well-to-well) uniformity, impact from loading, and hysteresis. We added a seventh in the form of a legitimate reference thermometer input and created an entirely new product category: Metrology Wells.

(By the way, Metrology Wells are the only products on the market supported by published specifications addressing every performance category in the EA-10/13. Our specs aren’t just hopes or guidelines. They apply to every Metrology Well we sell.)

Display accuracy

Dry-wells are typically calibrated by inserting a calibrated PRT into one of the wells and making adjustments to the calibrator’s internal control sensor based on the readings from the PRT. This has limited value because the unique characteristics of the reference PRT, which essentially become “calibrated into" the calibrator, are often quite different from the thermometers tested by the calibrator. This is complicated by the presence of significant thermal gradients in the block and inadequate sensor immersion into blocks that are simply too short.

Metrology Wells are different. Temperature gradients, loading effects, and hysteresis have been minimized to make the calibration of the display much more meaningful. We use only traceable, accredited PRTs to calibrate Metrology Wells and our proprietary electronics consistently demonstrate repeatable accuracy more than ten times better than our specs, which range from ±0.1 °C at the most commonly used temperatures to ±0.25 °C at 661 °C.

An application note is available to help better understand the uncertainties mentioned above. "Understanding the uncertainties associated with the use of Metrology Wells" is available from the Knowledge & Information tab on this page.

For even better accuracy, Metrology Wells may be ordered with built-in electronics for reading external PRTs with ITS-90 characterizations.

Stability

Heat sources from Fluke Calibration have long been known as the most stable heat sources in the world. It only gets better with Metrology Wells. Both low-temperature units (Models Fluke 9170 and Fluke 9171) are stable to ±0.005 °C over their full range. Even the 700 °C unit (Model 9173) achieves stability of ±0.03 °C. Better stability can only be found in fluid baths and primary fixed-point devices. The “off-the-shelf controllers" used by most dry-well manufacturers simply can’t provide this level of performance.

Axial uniformity

The EA-10/13 document suggests that dry-wells should include a zone of maximum temperature homogeneity, which extends for 40 mm (1.54 in), usually at the bottom of a well. Metrology Wells, however, combine our unique electronics with dual-zone control and more well depth than is found in dry-wells to provide homogeneous zones over 60 mm (2.36 in). Vertical gradients in these zones range from ±0.02 °C at 0 °C to ±0.4 °C at 700 °C.

What’s more, Metrology Wells actually have these specifications published for each unit, and we stand by them.

Radial uniformity

Radial uniformity is the difference in temperature between one well and another well. For poorly designed heat sources, or when large-diameter probes are used, these differences can be very large. For Metrology Wells, we define our specification as the largest temperature difference between the vertically homogeneous zones of any two wells that are each 6.4 mm (0.25 in) in diameter or smaller. The cold units (9170 and 9171) provide radial uniformity of ±0.01 °C and the hot units (9172 and 9173) range from ±0.01 °C to ±0.04 °C (at 700 °C).

Loading

Loading is defined as the change in temperature sensed by a reference thermometer inserted into the bottom of a well after the rest of the wells are filled with thermometers, too.

For Metrology Wells, loading effects are minimized for the same reasons that axial gradients are minimized. We use deeper wells than found in dry-wells. And we utilize proprietary dual-zone controls. Loading effects are as minimal as ±0.005 °C in the cold units.

Hysteresis

Thermal hysteresis exists far more in internal control sensors than in good-quality reference PRTs. It is evidenced by the difference in two external measurements of the same set-point temperature when that temperature is approached from two different directions (hotter or colder) and is usually largest at the midpoint of a heat source’s temperature range. It exists because control sensors are typically designed for ruggedness and do not have the “strain free" design characteristics of SPRTs, or even most PRTs. For Metrology Wells, hysteresis effects range from 0.025 °C to 0.07 °C.

Immersion depth

Immersion depth matters. Not only does it help minimize axial gradient and loading effects, it helps address the unique immersion characteristics of each thermometer tested in the heat source. Those characteristics include the location and size of the actual sensor within the probe, the width and thermal mass of the probe, and the lead wires used to connect the sensor to the outside world. Metrology Wells feature well depths of 203 mm (8 in) in the Models Fluke 9171, Fluke 9172, and Fluke 9173. The Model Fluke 9170 is 160 mm (6.3 in) deep to facilitate temperature of –45 °C.

Other great features

A large LCD display, numeric keypad, and on-screen menus make use of Metrology Wells simple and intuitive. The display shows the block temperature, built-in reference thermometer temperature, cutout temperature, stability criteria, and ramp rate. The user interface can be configured to display in English, French, or Chinese.

All four models come with an RS-232 serial interface and the Model 9930, Interface-it software. All are also compatible with Model 9938 MET/TEMP II software for completely automated calibrations of RTDs, thermocouples, and thermistors.

Even without a PC, Metrology Wells have four different preprogrammed calibration tasks that allow up to eight temperature set points with “ramp and soak" times between each. There is an automated “switch test" protocol that zeros in on the “dead-band" for thermal switches. And a dedicated °C/°F button allows for easy switching of temperature units.

Any of six standard inserts may be ordered with each unit, accommodating a variety of metric- and imperial-sized probe diameters. (See inset at right, click to enlarge image. Download the complete data sheet to view details.) And Metrology Wells are small enough and light enough to go anywhere.

Fluke 9170

The Model 9170 achieves the lowest temperatures of the series, reaching –45 °C in normal room conditions. The 9170 is stable to ±0.005 °C over its full temperature range (up to 140 °C) and has 160 mm (6.3 in) of immersion depth. With axial uniformity of ±0.02 °C and radial uniformity of ±0.01 °C, this model delivers exceptional uncertainty budgets and is perfect for a variety of pharmaceutical and other applications.

Fluke 9171

If you need more depth, the Model Fluke 9171 provides 203 mm (8 in) of immersion over temperatures from –30 °C all the way to 155 °C with full-range stability of ±0.005 °C. Just like the Fluke 9170, this dry-well has exceptional axial and radial uniformity. The display of the Fluke 9171 is calibrated to an accuracy of ±0.1 °C over its full range.

Fluke 9172

The Model Fluke 9172 provides temperatures from 35 °C to 425 °C with a calibrated display accurate to ±0.2 °C at 425 °C. In addition to exceptional accuracy, the 9172 is stable from ±0.005 °C to ±0.01 °C, depending on temperature. With 203 mm (8 in) of immersion, the Fluke 9172 significantly reduces stem conduction errors at high temperatures.

Fluke 9173

For work between 50 °C and 700 °C, the Model Fluke 9173 provides unmatched performance. The Fluke 9173 has a display accuracy of ±0.25 °C at 700 °C and an immersion depth of 203 mm (8 in). Stability and uniformity performance of this unit are enough to dramatically reduce uncertainty budgets for calibrations of thermometers at high temperatures.

Of course, there’s still a place in the world for dry-wells or “dry block" calibrators. In fact, Fluke Calibration makes and will continue to make some of the best performing, portable, fast dry-wells in the world. There’s still nothing better for a quick test of industrial temperature sensor performance.

Specifications

9170 9171 9172 9173
Range
(at 23 °C ambient)
–45 °C to 140 °C
(–49 °F to 284 °F)
–30 °C to 155 °C
(–22 °F to 311 °F)
35 °C to 425 °C
(95 °F to 797 °F)
50 °C to 700 °C†
(122 °F to 1292 °F)
Display Accuracy ± 0.1 °C full range ± 0.1 °C: 35 °C to 100 °C
± 0.15 °C: 100 °C to 225 °C
± 0.2 °C: 225 °C to 425 °C
7nbsp;
± 0.2 °C: 50 °C to 425 °C
± 0.25 °C: 425 °C to 660 °C
Stability ± 0.005 °C full range ± 0.005 °C: 35 °C to 100 °C
± 0.008 °C: 100 °C to 225 °C
± 0.01 °C: 225 °C to 425 °C
± 0.005 °C: 50 °C to 100 °C
± 0.01 °C: 100 °C to 425 °C
± 0.03 °C: 425 °C to 700 °C
Axial Uniformity
(60 mm)
± 0.1 °C at –45 °C
± 0.04 °C at –35 °C
± 0.02 °C at 0 °C
± 0.07 °C at 140 °C
7nbsp;
± 0.025 °C at –30 °C
± 0.02 °C at 0 °C± 0.07 °C at 155 °C
± 0.05 °C: 35 °C to 100 °C
± 0.1 °C: 100 °C to 225 °C
± 0.2 °C: 225 °C to 425 °C
± 0.1 °C: 50 °C to 100 °C
± 0.25 °C: 100 °C to 425 °C± 0.4 °C: 425 °C to 700 °C
Radial Uniformity ± 0.01 °C full range ± 0.01 °C: 35 °C to 100 °C
± 0.02 °C: 100 °C to 225 °C
± 0.025 °C: 225 °C to 425 °C
± 0.01 °C: 50 °C to 100 °C
± 0.025 °C: 100 °C to 425 °C
± 0.04 °C: 425 °C to 700 °C
Loading Effect
(with a 6.35 mm
reference probe and
three 6.35 mm probes)
± 0.02 °C at –45 °C
± 0.005 °C at –35 °C
± 0.01 °C at 140 °C
± 0.005 °C at –30 °C
± 0.005 °C at 0 °C
± 0.01 °C at 155 °C
± 0.01 °C full range ± 0.02 °C at 425 °C
± 0.04 °C at 700 °C
Hysteresis 0.025 °C 0.04 °C 0.07 °C
Well Depth 160 mm (6.3 in) 203 mm (8 in)
Resolution 0.001 °C
Display LCD, °C or °F, user-selectable
Key Pad
 
Ten key with decimal and +/- button. Function keys, menu key, and °C / °F key.
Cooling Time 44 min: 23 °C to –45 °C
19 min: 23 °C to –30 °C
19 min: 140 °C to 23 °C
30 min: 23 °C to –30 °C
25 min: 155 °C to 23 °C
220 min: 425 °C to 35 °C
100 min: 425 °C to 100 °C
235 min: 700 °C to 50 °C
153 min: 700 °C to 100 °C
Heating Time 32 min: 23 °C to 140 °C
45 min: –45 °C to 140 °C
44 min: 23 °C to 155 °C
56 min: –30 °C to 155 °C
27 min: 35 °C to 425 °C 46 min: 50 °C to 700 °C
Size (HxWxD) 366 x 203 x 323 mm (14.4 x 8 x 12.7 in)

Weight

14.2 kg (31.5 lb)

15 kg (33 lb)

13.2 kg (29 lb)

15 kg (33 lb)

Power 115 V ac (± 10 %), or
230 V ac (± 10 %), 50/60 Hz, 550 W
115 V ac (± 10 %), or
230 V ac (± 10 %), 50/60 Hz, 1025 W
Computer Interface RS-232 Interface 
Traceable Calibration Data at –45 °C, 0 °C, 50 °C, 100 °C, and 140 °C Data at –30 °C, 0 °C, 50 °C, 100 °C, and 155 °C Data at 100 °C, 150 °C, 250 °C, 350 °C, and 425 °C Data at 100 °C, 200 °C, 350 °C, 500 °C, and 660 °C
†Calibrated to 660 °C; reference thermometer recommended at higher temperatures.

Specifications

Built-in Reference Input
Temperature Range –200 °C to 962 °C (–328 °F to 1764 °F)
Resistance Range 0 Ω to 400 Ω, auto-ranging
Characterizations ITS-90 subranges 4, 6, 7, 8, 9, 10, and 11 Callendar-Van Dusen (CVD): R0, a, b, d
Resistance Accuracy 0 Ω to 20 Ω: 0.0005 W
20 Ω to 400 Ω: 25 ppm
Temperature Accuracy
(does not include probe uncertainty)
10 Ω PRTs:
± 0.013 °C at 0 °C
± 0.014 °C at 155 °C
± 0.019 °C at 425 °C
± 0.028 °C at 700 °C
25 Ω and 100 Ω PRTs:
± 0.005 °C at –100 °C
± 0.007 °C at 0 °C
± 0.011 °C at 155 °C
± 0.013 °C at 225 °C
± 0.019 °C at 425 °C
± 0.027 °C at 661 °C
Resistance Resolution 0 Ω to 20 Ω: 0.0001 Ω
20 Ω to 400 Ω: 0.001 Ω
Measurement Period 1 second
Probe Connection 4-wire with shield, 5-pin DIN connector
Calibration NVLAP  accredited calibration included
Model Name Description
9170-X

Metrology Well, –45 °C to 140 °C, w/INSX
(See insert image on Description tab.)

9170-X-R

Metrology Well, –45 °C to 140 °C, w/INSX, w/Built-In Reference
(See insert image on Description tab.)

9171-X

Metrology Well, –30 °C to 155 °C, w/INSX
(See insert image on Description tab.)

9171-X-R

Metrology Well, –30 °C to 155 °C, w/INSX, w/Built-In Reference
(See insert image on Description tab.)

9172-X

Metrology Well, 35 °C to 425 °C, w/INSX
(See insert image on Description tab.)

9172-X-R

Metrology Well, 35 °C to 425 °C, w/INSX, w/Built-In Reference
(See insert image on Description tab.)

9173-X

Metrology Well, 50 °C to 700 °C, w/INSX
(See insert image on Description tab.)

9173-X-R

Metrology Well, 50 °C to 700 °C, w/INSX, w/Built-In Reference
(See insert image on Description tab.)

Accessories common to all models:

Accessory Description
9170-CASE

Case, Carrying, 9170–3 Metrology Wells

9170-DCAS

Case, Transportation with Wheels, 9170–3 Metrology Wells

9170-INSA

Insert “A” 9170, Al, Misc Holes

9170-INSB

Insert “B” 9170, Al, Misc Holes

9170-INSC

Insert “C” 9170, Al, 0.25-inch Holes

9170-INSD

Insert “D” 9170, Al, Metric Comparison Holes

9170-INSE

Insert “E” 9170, Al, Misc Metric Holes, w/0.25-inch Ref Hole

9170-INSF

Insert “F” 9170, Al, Metric Comparison Holes, w/0.25-inch Ref Hole

9170-INSZ

Insert “Z” 9170, Al, Blank

9171-INSA

Insert “A” 9171, Al, Misc Holes

9171-INSB

Insert “B” 9171, Al, Comparison Holes

9171-INSC

Insert “C” 9171, Al, 0.25-inch Holes

9171-INSD

Insert “D” 9171, Al, Comparison Metric Holes

9171-INSE

Insert “E” 9171, Al, Misc Metric Holes, w/0.25-inch Ref Hole

9171-INSF

Insert “F” 9171, Al, Metric Comparison Holes, w/0.25-inch Ref Hole

9171-INSZ

Insert “Z” 9171, Al, Blank

9172-INSA

Insert “A” 9172, Brass, Misc Holes

9172-INSB

Insert “B” 9172, Brass, Comparison Holes

9172-INSC

Insert “C” 9172, Brass, 0.25-inch Holes

9172-INSD

Insert “D” 9172, Brass, Metric Comparison Holes

9172-INSE

Insert “E” 9172, Brass, Misc Metric Holes, w/0.25-inch Ref Hole

9172-INSF

Insert “F” 9172, Brass, Metric Comparison Holes, w/0.25-inch Ref Hole

9172-INSZ

Insert “Z” 9172, Brass, Blank

9173-INSA

Insert “A” 9173, Al-Brnz, Misc Holes

9173-INSB

Insert “B” 9173, Al-Brnz, Comparison Holes

9173-INSC

Insert “C” 9173, Al-Brnz, 0.25-inch Holes

9173-INSD

Insert “D” 9173, Al-Brnz, Comparison Metric Holes

9173-INSE

Insert “E” 9173, Al-Brnz, Misc Metric Holes, w/0.25-inch Ref Hole

9173-INSF

Insert “F” 9173, Al-Brnz, Metric Comparison Holes, w/0.25-inch Ref Hole

9173-INSZ

Insert “Z” 9173, Al-Brnz, Blank

9170-INSY

Insert Custom 9170
Custom insert pricing is based on a maximum of eight holes.  Please contact your local sales representative if you have special requirements.

9171-INSY

Insert Custom 9171
Custom insert pricing is based on a maximum of eight holes.  Please contact your local sales representative if you have special requirements.

9172-INSY

Insert Custom 9172
Custom insert pricing is based on a maximum of eight holes.  Please contact your local sales representative if you have special requirements.

9173-INSY

Insert Custom 9173
Custom insert pricing is based on a maximum of eight holes.  Please contact your local sales representative if you have special requirements.  9173-INSY insert hole sizes must be greater than 2 mm (1/16 inch).

HART DRYWELL CABLE

An interface cable kit that includes a null modem to connect the Fluke 754 with Fluke Calibration dry-wells and Micro-Baths to automate and document the calibration of temperature sensors and transmitters in the field or at the bench.

Priority Gold Instrument CarePlan

Fluke Calibration Priority Gold Instrument CarePlans are available for most calibration products. Please contact your local Fluke Calibration sales representative for details or to request a quote. You may also call the Customer Care Center at 877-355-3225 or send email to careplans@flukecal.com.

Silver CarePlan

Fluke Calibration Silver CarePlans are available for most calibration products. Please contact your local Fluke Calibration sales representative for details or to request a quote. You may also call the Customer Care Center at 877-355-3225 or send email to careplans@flukecal.com.

Product Manuals
application/pdf icon 9170 Statement of Memory Volitility (35.19 KB)
application/pdf icon 917X Series Metrology Well Technical Guide (English) (10.95 MB)
application/pdf icon 917X Series User Guide (1.1 MB)
application/pdf icon 917X Series User Guide (Chinese) (1.55 MB)
application/pdf icon 917X Series User Guide (French) (1.3 MB)
application/pdf icon 917X Series User Guide (German) (1.29 MB)
application/pdf icon 917X シリーズ・ユーザー・ガイド(日本語) (1.45 MB)
application/pdf icon 917X Series User Guide (Russian) (1.23 MB)
application/pdf icon 917X Series User Guide (Spanish) (1.3 MB)
application/pdf icon 917X Series User Guide Supplement (167.95 KB)
application/pdf icon 917x Technical Guide (11.04 MB)
application/pdf icon 917x Technical Guide Supplement (178.56 KB)
Brochures
application/pdf icon Industrial Temperature Calibrators Workload Matrix (96.74 KB)
Application Notes
application/pdf icon Dry-block product comparison table (233.1 KB)
application/pdf icon Eliminating Sensor Errors in Temperature Control Loop Calibrations (1.49 MB)
application/pdf icon Establishment of a Secondary Temperature Calibration Laboratory (3.09 MB)
application/pdf icon How to Calibrate an RTD or Platinum Resistance Thermometer (PRT) (652.16 KB)
application/pdf icon Kalibrieren eines RTD oder Platin-Widerstandsthermometers (PRT) (German) (828.03 KB)
application/pdf icon Comment étalonner unde sonde RTD ou sonde à résistance de platine (PRT) (French) (834.22 KB)
application/pdf icon Cómo calibrar una RTD o un sensor de temperatura (Spanish) (819.7 KB)
application/pdf icon English: Thermocouple App Notes Series, 2 of 4 - How to Select Thermocouple Calibration Equipment (2.51 MB)
application/pdf icon German: Thermocouple App Notes Series, 2 of 4 - Auswahl von Geräten zur Kalibrierung von Thermoelementen (2.21 MB)
application/pdf icon French: Thermocouple App Notes Series, 2 of 4 - Guide de sélection d'équipement d'étalonnage de thermocouple (2.21 MB)
application/pdf icon Russian: Thermocouple App Notes Series, 2 of 4 - Как выбрать оборудование для калибровки термопары (2.26 MB)
application/pdf icon Spanish: Thermocouple App Notes Series, 2 of 4 - Cómo elegir un equipo de calibración de termopares (2.21 MB)
application/pdf icon Improving loop calibration temperature accuracy (991.83 KB)
application/pdf icon Verbesserung der Temperaturgenauigkeit bei der Kalibrierung von Messketten (German) (793.62 KB)
application/pdf icon Selecting an Industrial Temperature Calibrator (1.6 MB)
application/pdf icon Auswahl eines Temperaturkalibrators für den Einsatz in der Industrie (German) (1.43 MB)
application/pdf icon Sélection d'un calibrateur de température industriel (French) (1.42 MB)
application/pdf icon Selección de un calibrador de temperatura industrial (Spanish) (1.42 MB)
application/pdf icon Выбор промышленного калибратора температуры (Russian) (1.43 MB)
application/pdf icon Temperature Calibration Equipment: A Technician's Guide (1.62 MB)
application/pdf icon Temperature calibration: Tips and tricks from the real world (2.19 MB)
application/pdf icon Temperature measurement and calibration: What every instrument technician should know (1.65 MB)
application/pdf icon Temperaturmessung und -kalibrierung (German) (650.54 KB)
application/pdf icon Mesure et étalonnage thermique (French) (655.57 KB)
application/pdf icon Medición y calibración de temperatura (Spanish) (651.42 KB)
application/pdf icon Testing Temperature Switches Using Metrology Wells (3.68 MB)
application/pdf icon English: Thermocouple App Notes Series, 1 of 4 - Thermocouple Fundamentals (2.5 MB)
application/pdf icon Korean: 열전대 응용시리즈 첫번째 - 열전대의 기본사항 (2.28 MB)
application/pdf icon German: Thermocouple App Notes Series, 1 of 4 - Grundlagen zu Thermoelementen (2.22 MB)
application/pdf icon French: Thermocouple App Notes Series, 1 of 4 - L'essentiel des thermocouples (2.22 MB)
application/pdf icon Spanish: Thermocouple App Notes Series, 1 of 4 - Nociones básicas de los termopares (2.22 MB)
application/pdf icon Russian: Thermocouple App Notes Series, 1 of 4 - Основные сведения о термопаре (2.29 MB)
application/pdf icon Understanding the Uncertainties Associated with the Use of Metrology Wells (2.34 MB)
application/pdf icon Why calibrate temperature devices? (977.05 KB)
application/pdf icon Does Immersion Depth Really Matter? (745.44 KB)
application/pdf icon Principles of Metrology (400.44 KB)
Data Sheets
application/pdf icon 9170 Series Metrology Well Calibrators Technical Data (996.05 KB)
application/pdf icon メトロロジー・ウエル9170シリーズ テクニカル・データ (375.89 KB)
Firmware
917X Firmware
Papers / Articles
application/pdf icon Having Confidence in Specifications (61 KB)
application/pdf icon Common Problems in Achieving Maximum Performance from Dry-Well Thermometer Calibrators (1.21 MB)
application/pdf icon Improvement Study on the Use of Dry-Well Calibrators for PRT Calibration (542.55 KB)
Metrology Wells Versus Dry-Wells: Do Vertical Gradients Really Matter?
application/pdf icon Proper Platinum Resistance Thermometer Calibration Uncertainty Analysis (351.32 KB)
Selecting a Dry-Well (Dry-Block) Temperature Calibrator
application/pdf icon The Development of a High-Temperature PRT Calibration Process Based on Dry-Block Calibrators (60.55 KB)
Video
How to Calibrate a Digital Thermometer with a Dry-Block Calibrator and with Freezing and Boiling Water
Introduction to Dry Block Calibrators
  • Printer-friendly version »
  • Home
  • Products
    • New Products
    • Electrical Calibration
      • Electrical Standards
      • Electrical Calibrators
      • Bench Multimeters
      • Electrical Calibration Software
    • RF Calibration
      • RF Reference Sources
      • RF Calibration Accessories
      • RF Calibration Software
    • Data Acquisition and Test Equipment
      • Bench Multimeters
      • Data Acquisition
      • Data Acquisition Software
    • Temperature Calibration
      • ITS-90 Temperature Standards
        • ITS-90 Fixed-point cells
        • Standard Platinum Resistance Thermometers
        • Maintenance Apparatus
        • Liquid Nitrogen Comparison Calibrator
        • Resistance Bridges
        • Standard Resistors
      • Calibration Baths
        • Compact Calibration Baths
        • Standard Calibration Baths
        • Special Application Baths
        • Bath Accessories
        • Bath Controllers
        • Bath Fluids
      • Industrial Calibrators
        • Field Metrology Wells
        • Metrology Wells
        • Handheld Calibrators
        • Field Dry-Block Calibrators
        • Micro Baths
        • Infrared Calibrators
        • Thermocouple Furnaces
        • Dual Block Dry-Well
        • Zero-point Dry-Well
      • Probes / Sensors
        • Platinum Resistance Thermometers (PRTs)
        • Thermistors
        • Thermocouples
      • Digital Thermometer Readouts
      • Multifunction Calibrators
      • Temperature Calibration Software
    • Humidity Calibration
      • Humidity Generators
      • Humidity Data Loggers and Monitors
    • Pressure Calibration
      • Piston Gauges
        • NMI Piston Gauges
        • Absolute Piston Gauges
        • High Pressure Pneumatic Piston Gauges
        • Hydraulic Piston Gauges
        • Piston Gauge Accessories
      • Automated Pressure Controller / Calibrators
        • Low Pressure Controllers / Calibrators
        • Pneumatic Pressure Controllers / Calibrators
        • High Pressure Pneumatic Controller / Calibrators
        • Hydraulic Controller / Calibrators
      • Pressure Monitors
        • Low Pressure Monitors
        • Digital Pressure Gauges
        • Reference Pressure Monitors
      • Deadweight Testers
        • Pneumatic Deadweight Testers
        • Oil Deadweight Testers
        • Water Deadweight Testers
        • High-Pressure Hydraulic Deadweight Testers
        • Deadweight Tester Accessories
      • Manual Pressure Calibration
        • Pressure Calibrators
        • Pneumatic Pressure Control
        • Hydraulic Pressure Comparators / Pumps
      • Handheld Pressure Calibrators
      • Air Data Calibration
      • Environmental Monitors
      • Pressure Calibration Accessories
      • Pressure Calibration Custom Systems
      • Pressure Calibration Software
    • Flow Calibration
      • Gas Flow Standards
      • Gas Flow Accessories
      • GFS Primary Gravimetric Flow Standard
      • Flow Calibration Software
    • Process Calibration Tools
      • Temperature Calibrators
        • Handheld Temperature Calibrators
        • Dry-Block Calibrators and Micro-Baths
        • Precision Digital Thermometers
        • Temperature Probes
        • Infrared Calibrators
        • Hygro Thermometer with Data Logging
      • Pressure Calibrators
        • Digital Pressure Calibrators
        • Handheld Pressure Calibrators
        • Deadweight Testers
        • Precision Digital Pressure Gauges
        • Calibration Hand Pumps
      • Multifunction Calibrators
      • mA Loop Calibrators
      • Process Calibration Software
    • Calibration Software
      • MET/CAL® Software
      • MET/CAL® Support
      • Asset Management Software
      • Temperature Calibration Software
      • Pressure Calibration Software
      • Flow Calibration Software
      • Mechanical / Dimensional Calibration Software
    • Service and Support
    • All Calibration Instruments
  • Purchase Info
    • Where to Buy
    • Request a Quote
    • Request a Demo
    • Request a Sales Consultation
    • Certified Pre-Owned Equipment
    • General Services Administration (GSA)
    • Financing Program
    • National Stock Numbers (NSNs)
    • Payment Options and Tax Info
  • News
    • Press Releases
    • Promotions
    • Industry Links
    • Metrology Salary Survey
  • Training and Events
    • Conferences and Exhibitions
    • Training Courses
    • User Group Meetings
    • Web Seminars
      • Live Seminars
      • On-Demand Seminars
  • Literature and Education
    • Education Hub
    • About Calibration
    • Articles and Education
    • Product Literature
    • Product Manuals (User Guides)
    • Videos and Virtual Demos
    • Blog
  • Service and Support
    • Service Request (RMA)
    • Service Plans
    • Technical Support
    • Knowledge Base
    • Accreditations
    • Authorized Service Centers
    • Calibration Certificates
    • Community Forum
    • My MET/SUPPORT
      • Activate
      • Procedures
      • Software
      • Technical Bulletins
      • Priority Support
      • Manuals
    • Product Manuals (User Guides)
    • Safety Data Sheets (SDS)
    • Safety, Service, and Product Notices
    • Software Downloads
    • Tools
      • PT100 Calculator
      • ITS-90 Reference Function Calculator
      • Thermocouple Table Voltage Calculator
      • Thermocouple Voltage to Temperature Calculator
  • About Us
    • Contact Us
    • Visit Us
    • Employment
    • Fluke Calibration
      • Hart Scientific Temperature Calibration
      • DH Instruments Pressure and Flow Calibration
      • Pressurements Pressure Calibration
      • Ruska Pressure Calibration
    • Fluke Companies
    • Integrity and Compliance
    • Frequently Asked Questions
Home|Products|Temperature Calibration|Industrial Calibrators|Metrology Wells|9170, 9171, 9172, & 9173 Metrology Well Calibrators

Sidebar Request a Quote

Request a quote

Your information is protected by our privacy policy.

©1995-2023 Fluke Corporation
             

Secondary menu

  • Disclaimer
  • Privacy Statement
  • Terms of Use
  • Terms of Sale