2680 Series Data Acquisition Systems

2680 Series Data Acquisition Systems
2680 Series Data Acquisition Systems
2680 Series Data Acquisition Systems
2680 Series Data Acquisition Systems
2680 Series Data Acquisition Systems
2680 Series Data Acquisition Systems
2680 Series Data Acquisition Systems
2680 Series Data Acquisition Systems
Request a quote
  • Highlights
  • Description
  • Specifications
  • Models and Accessories
  • Knowledge and Information

Standalone or networked precision multi-channel DAQ
The Fluke 2680 Series data acquisition systems combine the best of lab precision with the rugged flexibility required in rapidly changing industrial applications. Whether you choose the 2680A Data Acquisition System with high-speed 10/100BastT Ethernet network support or the 2686A Data Logging System, you can seamlessly expand your system any time from 20 to more than 2,000 channels, just by adding modules and chassis.

Both models feature six slots in each chassis that you can fill with modules as needed to meet your application requirements. Five slots in each chassis are available for any combination of 2680 Series 20-channel analog input modules. The sixth slot is reserved for a 2680 Series digital I/O relay module to add control capabilities to your system. If you don't need the sixth slot for control, you can plug in an additional analog input module, increasing your channel count to 120 in a single chassis.

You can also link multiple 120-channel systems together seamlessly for the widest possible view of your data. And with TCP/IP connectivity you can connect to existing LANs to distribute information wherever it needs to go. Whether you need speed and throughput, isolated precision, or digital I/O and relays, the Fluke 2680 Series can scale up to thousands of channels to meet your needs.

Features at a glance:

  • 20 to 120 universal analog inputs per chassis; systems to +2,000 channels
  • Stand-alone data logger operation with the 2686A
  • Large scalable LAN systems using the 2680A with 10BaseT/100BaseT
  • Two types of Universal Input Modules: high-isolation precision modules or fast scan modules, with 16- to 18-bit resolution
  • Throughput of more than 3,000 channels-per-second-per-chassis with 2680A-FAI modules
  • Superior thermocouple measurement accuracy (J, K, R, S, T, N, I, U, C, B)
  • 20 digital I/O and 8 form C, 1 Amp relay output modules for direct control of equipment
  • Up to 300V input isolation, 1600V transient overvoltage protection (2680A-PAI)
  • Universal input conditioning for any input, on any channel, in any combination (V dc, V ac, Ohms, frequency, RTD, thermocouple, thermistor or current
  • ATA flash memory card for stand-slone operation - from 16 MB to 1 GB (2686A only)
  • Multiple power sources: 100 to 240 V and 9 V to 45 V dc
  • Includes Fluke DAQ Software » which: Controls all 2680 Series functions, provides real-time and historical and also communicates with and 2645A NetDAQ » products

The Fluke 2680 Series offers the choice of networked data acquisition, stand-alone data logging, or a combination of both. Choose from two basic chassis models:

2680A Data Acquisition System chassis
The Fluke 2680A Data Acquisition System is the choice for multi-channel applications requiring reliable Ethernet communications. It features a front-end style data acquisition system that communicates and distributes data anywhere you need it to go. The 10BaseT and 100BaseT communications interface makes it compatible with both older and newer network installations.

2686A Data Logging System chassis
The Fluke 2686A Data Logging System writes data to a memory card for easy retrieval and storage, making it ideal for remote locations and mobile or non-computer assisted data logging applications. The system comes with a 16 MB ATA memory card and supports ATA flash memory cards of up to 1 GB to provide the memory capacity you need. The 2686A is easily configured for stand-alone data logging operations by simply selecting a preset configuration from the memory card. It can also be used in networks in tandem with the 2680A to provide the extra data security of a memory card.

Scale your system to meet your needs
With the Fluke 2680A and the 2686A, you can seamlessly expand your system from 20 to more than 2,000 channels just by adding modules and chassis. Both models feature six slots in each chassis that you can fill with modules as needed to meet your application requirements. Five slots in each chassis are available for any combination of 20-channel analog input modules. The sixth slot is also available for a digital I/O relay module to add control capabilities to your system. If you don't need the sixth slot for control, you can plug in an additional analog input module, increasing your input channel count to 120 in one chassis.

You can also link multiple 120-channel systems together seamlessly for the widest possible view of your data. And, with TCP/IP connectivity, you can connect to existing LANs to distribute information wherever it needs to go.

Whether you need speed and throughput, isolated precision, or digital I/O and relays, the Fluke 2680 Series can scale up to thousands of channels to meet your needs. Buy just the modules you need in the combinations you need and expand your system as your requirements grow.

2680A-FAI: the speed to capture dynamic process changes
The Fluke 2680A-FAI (Fast Analog Input) is a perfect choice when you need a lot of information in a hurry and still need to maintain a high degree of accuracy for your measurements. The 2680A-FAI module provides chassis throughput rates of more than 3,000 channels-per-second. Specially manufactured field effect transistors (FETs) allow up to + 50 V input, and channel-to-channel isolation well above the 15 V industry norm, to give you more confidence in the integrity of your measurements.

2680A-PAI provides high precision and high isolation for the most demanding jobs
The Fluke 2680A-PAI (Precision Analog Input) 20-channel high-precision, high-isolation module serves the most demanding jobs where precision is paramount and isolation is critical. Some of the most notable applications for this module include temperature measurement in semiconductor and pharmaceutical manufacturing, as well as nuclear plant performance monitoring. The 2680A-PAI module offers 300 V of isolation on two channels and 150 V on 18 channels, as well as 18-bit resolution and excellent thermocouple accuracy, all in a scalable system.

Both the 2680A-FAI and the 2680A-PAI modules support a wide range of inputs including dc volts, ac volts, RTD, Ohms, thermocouple, thermistor, dc current, ac current, and frequency. Other sensors and transducers, such as load cells, pressure sensors, and displacement sensors can be easily incorporated into your measurement system.

2680A-DIO: Digital I/O and relay outputs add control
For data acquisition systems that also require control functionality, the Fluke 2680A-DIO digital I/O and relay output module provides 20 digital I/O and eight hard-contact 1 Amp form-C relays. This equips each chassis to respond to a wide range of alarm or control situations. The 2680A-DIO also includes an up/down counter with preset start count capability, so you do not need to begin all counts at zero.

2680A-180: Universal Input Module requires no external signal conditioning
Fluke’s patented Universal Input Module is a special connector that is included with Fluke data acquisition products, providing unparalleled thermocouple accuracy and compatibility with a broad range of diverse inputs. The signal conditioning built into Fluke data acquisition products enables you to easily measure just about any electrical or physical parameter without changing hardware or adding external signal conditioning. You can connect any combination of dc voltage, ac voltage, thermocouples, current, RTD, resistance (2- or 4-wire) or frequency measurement inputs directly to the Universal Input Module.

Fluke DAQ Software makes it easy to get the most out of your data
Each Fluke 2680A and 2686A comes with our powerful, highly flexible, yet easy-to-use Fluke DAQ Configuration Software ». Fluke DAQ allows you to configure the 2680 Series for:

  • Input type
  • Alarms
  • Math functions
  • Totalizer function
  • Digital I/O lines
  • Scan speed
  • Interval
  • Trigger type

You can also user Fluke DAQ Software to set up data files, collect and chart data in real-time or historical mode, and manage PC card files. And you can use Fluke DAQ to collect data from your system the way you need to and distribute it where you want it. You can share data with others, anywhere on your LAN or anywhere around the world using Web servers.

Fluke DAQ Software also enables you to integrate Fluke NetDAQ® data acquisition products (2640A and 2645A) into your 2680 Series system, providing almost unlimited channels working together seamlessly.
Download FlukeDAQ 4.0 demonstration software.

Optional software extends system capabilities
Fluke 2680A-904: Trend Link software
Trend Link for the 2680 Series is a comprehensive and powerful trend plotting software package. The Trend Link software allows users to access, view, and analyze tremendous amounts of historical and real time data in a trending or chart recorder-like display. With Trend Link, you can zoom in on points of interest in your data, or zoom out to display a wide overview of long-term trends. It can calculate basic statistics such as the mean and standard deviation on individual trends. Trend Link can define, save and display multiple charts to view logged data in different ways or arrangements. Trend Link is also capable of exporting selected sections of the data for analysis or manipulation in other software.

Fluke has partnered with industrial software developer Indusoft to create additional tools to extend the power of your 2680 Series system. These optional software tools enable you to create HMIs and develop custom applications that interact with other equipment and software packages.

Fluke 2680A-DEVSW: HMI development software
The optional 2680A-DEVSW Indusoft Web Studio development software is an object-oriented development program that works with Fluke DAQ software. This unique development software enables programmers and non-programmers to develop modern HMIs which open graphical windows to your application.

Fluke 2680A-OPC: Communicate with any application supporting OLE for Process Control
This OPC server software provides the configuration interface for the 2680 Series and also offers a common communication link to any software package that supports OPC. Create custom applications using 2680A-OPC software and just about any popular industrial software package such as Wonderware™, LabVIEW™ Test Point, or Indusoft Web Studio, as well as software from Canary Labs, Daisy Labs, and others. Open, non-proprietary OPC support enables you to user the software you choose or the software you create.

Fluke 2680A-DLL library: For developing or modifying applications
The 2680A DLL library provides the full DLL toolbox for application software developers who need to write original programs for the 2680 Series, using Visual C++, Visual Basic, and other languages.

Technical Specifications
Channel capacity (2680A or 2686A)
20 to 120 channels per chassis (6 analog input modules of 20 channels each)
One master alarm (open collector) per chassis
Communications: 10BaseT/100BaseT, TCP/IP via RJ45 connector, Cat 5
Math functions In addition to its analog and digital input channels, each system supports 60 computed channels. Calculations include: time & rate, addition, subtraction, multiplication, division, log, natural log, exponent, square root, absolute value, integer function and average.
Measurement speed (2680A-PAI)
Slow: 6 readings/second nominal
Medium: 41 (50 Hz), 48 (60 Hz) readings/second nominal
Fast: 143 readings/second for VAC nominal, 140 readings/second on 300 Ω range, 37 readings/second on 3 MΩ range)
Measurement speed (2680A-FAI)
Slow: 45 (50 Hz), 54 (60 Hz) readings/second nominal
Medium: 200 readings/second nominal
Fast: 1000 readings/second nominal (5 readings/second for VAC nominal, 370 readings/second on 300 Ω range, 44 readings/second on 3 MΩ range)
Analog to digital converter
2680A-PAI: 18 bit, multi-slope type
2680A-FAI: 16 bit, multi-slope type
Common mode rejection
2680A-PAI: AC: > 120 dB (50/60 Hz, + 0.1 % max 1 kΩ source imbalance) DC: > 120 dB
2680A-FAI: AC: > 100 dB (50/60 Hz, + 0.1 % max 1 kΩ source imbalance) DC: > 100 dB
Normal mode rejection 50 dB @ 50/60 Hz, ± 0.1 %
Common mode voltage maximum
2680A-PAI: 300 V DC or v AC rms (channels 1,11); 25% V dc or V ac rms (all other channels)
2680A-FAI: 50 V dc or 30 V ac rms (all channels)
Totalizing input (2680A-DIO)
Pre-settable starting count up/down counter DC coupled, non-isolated, max + 30 V, min – 4 V
Max count: 4,292,967,295
Minimum signal: 2 V pead
Threshold: 1.4 V
Rate: 0-5 kHz (debounce off)
Hysteresis: 500 mV
Input debouncing: none or 1.66 ms
Digital Inputs/Outputs: 20 (2680A-DIO)
Threshold: 1.4 V
Hysteresis: 500 mV
Maximum input: +30V, min –4 V; non-isolated Logical “zero” output:
Logical “zero” output: 0.8 V max |out = -1.0 mA (1 LSTTL load equivalent)
  1.8 V max |out = -20 mA
  3.25 V max |out = -50 mA
  Output voltage depends on external load
  3.8 V min |out = 0.05 mA
  (1 LSTTL load equivalent)
Relays (2680A-DIO)
Quantity: 8
Type: form C; DPST
Current: 1 amp, non-inductive
Operation time: 75 ms
Alarm associations (2680A-DIO) Each Digital I/O may be randomly assigned as a digital input, status output, or alarm output (associated with any input channel or channels)
Trigger input
Minimum pulse: 5 µs
Minimum latency: 100 ms
Input “High”: 2.0 V min, 7.0 V max
Input “Low”: -0.6 V min, 0.8 V max non-isolated, contact closure and TTL compatible
Clock Accurate to within 1 minute/month for 0 °C to 50 °C range
General Specifications
Power, battery life 100 to 240 V ac, 50 or 60 Hz 100 VA max, or 9 to 45 V dc (50 W max – all slots filled + memory card installed) (if both sources are applied simultaneously, the greater of ac or dc is used) at 120 V ac the equivalent dc voltage ~14.5 V
Temperature, humidity (non-condensing)
Operating: -20 °C to 28 °C, < 90 % RH:
  28 °C to 40 °C, < 75 % RH;
  40 °C to 60 °C, < 50 % RH
Storage: -40 °C to 70 ° C, 5 % to 95 % RH
Altitude
Operating: 2000 m
Storage: 12,200 m
Standards
All inputs: IEC Overvoltage rating Category II Product conforms to the following safety and emisions standards:
  EN50082-2
  EN55022-1
  EN550aa class A
  EN610000-4-2, 3, 4, 6, 8
  EN61326
  EN61010-1, CAT II
  CSA C22.2 No. 1010.1
Operating Temperature - 20 °C to 60 °C (-4 °F to +140 °F)
Storage Temperature -40 °C to 70 °C (-40 °F to +158 °F)
Size 18.6” x 17 “ x 9.3”
(473 mm x 423 mm x 237 mm)
Weight 2680A/2686A chassis only: 18.86 lbs (8.47 kg)
2680A-FAI: 1.74 lbs. (0.79 kg)
2680A-PAI: 2.66 lbs, (1.21 kg)
2680A-DIO: 1.75 lbs. (0.80 kg)
Interfaces Ethernet: conforms to IEEE 802.3 Ethernet standard, compatible with 100BaseT and 10BaseT standards, uses TCP/IP protocal RS-232C: for calibration only
System Requirements IBM compatible, Pentium II processor
Microsoft Windows® NT/98/2000/XP
64 MB RAM
25% MB free hard disk space
VGA or SVGA display, 100 % IBM compatible with 2 MB Video RAM (VRAM)
CD-ROM drive
Microsoft Internet Explorer 4.0 or later

Model Name Description
2680A

Data Acquisition System Chassis

  • Fluke DAQ Software
  • Product manual on CD
  • Alarm/Trigger/DC Power Connector
  • 1 meter cross-over, Ethernet cable
  • Line Cord
  • Type T thermocouple
2686A

Data Logging System Chassis

  • Fluke DAQ Software
  • Product manual on CD
  • Alarm/Trigger/DC Power Connector
  • 1 meter cross-over, Ethernet cable
  • Line Cord
  • Type T thermocouple
  • 1 GB flash memory card
2680A-FAI

Fast Analog Input Module

  • 20 universal channels
  • 50 V max isolation
  • 16-bit resolution
  • 1000 ch/sec scan rate
  • Includes universal input module 2680A-180
  • Statement of Calibration Practices
2680A-PAI

Precision Analog Input Module

  • 20 universal channels
  • 300 V Max isolation
  • 18-bit resolution
  • 140 ch/sec scan rate
  • Includes universal input module 2680A-180
  • Statement of Calibration Practices
2680A-APSW v6.0

Fluke DAQ 6.0 Application Software for Fluke data acquisition products.
Click here for more information »

Accessories common to all models:

Accessory Description
2680A/CASE

Hard Carrying Case for 2680 Series

Y2680

19-inch rack mount kit for Fluke 2680 Series

2680A-102

2680A-DIO connector module, extra connector

2680A-180

Universal Input Module, extra connector

2680A-DLL

DLL Library for Fluke 2680 Series

2680A-DEVSW

Indusoft Web Studio development software for Fluke DAQ

This product is no longer available.

2680A-OPC

OPC software for Fluke 2680 Series

This product is no longer available separately. However, it is included as part of 2680A-APSW 6.0.

2620A-101

2620A-101 Current Shunt Resistors

Product Manuals
application/pdf icon 2680A/2686A Getting Started Guide (English) (9.12 MB)
application/pdf icon 2680A/2686A Getting Started Guide Supplement (317.42 KB)
application/pdf icon 2680A/2686A Guide d'introduction (French) (9.17 MB)
application/pdf icon 2680A/2686A Erste Schritte (German) (9.15 MB)
application/pdf icon 2680A/2686A Guía de funcionamiento básico (Spanish) (9.15 MB)
application/pdf icon 2680A/2686A Getting Started Guide (Korean) (11.45 MB)
application/pdf icon 2680A/2686A Getting Started Guide (Chinese, Simplified) (13.37 MB)
application/pdf icon 2680A/2686A Users Manual (English) (13.41 MB)
application/pdf icon 2680A/2686A Users Manual Supplement (English) (285.9 KB)
application/pdf icon 2680A/2686A Statement of Memory Volitility (49.98 KB)
application/pdf icon 268XA Service (6.28 MB)
application/pdf icon 2680A/2686A Service Manual Supplement (285.75 KB)
application/pdf icon Y5537A Instruction Sheet (377.05 KB)
Brochures
application/pdf icon Data Acquisition Family Brochure (3.13 MB)
Application Notes
application/pdf icon Viewing CSV Data Files in Microsoft Excel® Spreadsheet Software (1.04 MB)
application/pdf icon 3-Wire RTD Measurement Application Note (621.79 KB)
application/pdf icon Data Acquisition Speed, Accuracy, and Resolution Specifications (1.39 MB)
application/pdf icon How to Configure a Fluke Data Acquisition System for Use with Transducers (973.36 KB)
application/pdf icon Reading Memory Cards from Hydra 2635A Data Bucket in a PC Card Slot (1.34 MB)
application/pdf icon The Hidden Costs of “Low Cost” Data Acquisition Systems (73.58 KB)
Data Sheets
application/pdf icon 2680 Series Data Acquisition Systems (2.81 MB)
application/pdf icon Application, Trending and Development Software for Fluke NetDAQ® and 2680 Series Data Acquisition Products (399.11 KB)
Software
2680A-904 Trend Link v10, 14 day Demo Download
Fluke DAQ Software
Instruction Sheets
application/pdf icon 2680A-RF24G 120 / 230 Wireless Network Bridge Instruction Sheet (191.78 KB)
application/pdf icon Model Y5537A Rack Mount Kit Instruction Sheet (134.68 KB)
LabView Drivers
National Instruments LabView® driver for Fluke data acquisition instruments
  • Printer-friendly version »
  • Home
  • Products
    • New Products
    • Electrical Calibration
      • Electrical Standards
      • Electrical Calibrators
      • Bench Multimeters
      • Electrical Calibration Software
    • RF Calibration
      • RF Reference Sources
      • RF Calibration Accessories
      • RF Calibration Software
    • Data Acquisition and Test Equipment
      • Bench Multimeters
      • Data Acquisition
      • Data Acquisition Software
    • Temperature Calibration
      • ITS-90 Temperature Standards
        • ITS-90 Fixed-point cells
        • Standard Platinum Resistance Thermometers
        • Maintenance Apparatus
        • Liquid Nitrogen Comparison Calibrator
        • Resistance Bridges
        • Standard Resistors
      • Calibration Baths
        • Compact Calibration Baths
        • Standard Calibration Baths
        • Special Application Baths
        • Bath Accessories
        • Bath Controllers
        • Bath Fluids
      • Industrial Calibrators
        • Field Metrology Wells
        • Metrology Wells
        • Handheld Calibrators
        • Field Dry-Block Calibrators
        • Micro Baths
        • Infrared Calibrators
        • Thermocouple Furnaces
        • Dual Block Dry-Well
        • Zero-point Dry-Well
      • Probes / Sensors
        • Platinum Resistance Thermometers (PRTs)
        • Thermistors
        • Thermocouples
      • Digital Thermometer Readouts
      • Multifunction Calibrators
      • Temperature Calibration Software
    • Humidity Calibration
      • Humidity Generators
      • Humidity Data Loggers and Monitors
    • Pressure Calibration
      • Piston Gauges
        • NMI Piston Gauges
        • Absolute Piston Gauges
        • High Pressure Pneumatic Piston Gauges
        • Hydraulic Piston Gauges
        • Piston Gauge Accessories
      • Automated Pressure Controller / Calibrators
        • Low Pressure Controllers / Calibrators
        • Pneumatic Pressure Controllers / Calibrators
        • High Pressure Pneumatic Controller / Calibrators
        • Hydraulic Controller / Calibrators
      • Pressure Monitors
        • Low Pressure Monitors
        • Digital Pressure Gauges
        • Reference Pressure Monitors
      • Deadweight Testers
        • Pneumatic Deadweight Testers
        • Oil Deadweight Testers
        • Water Deadweight Testers
        • High-Pressure Hydraulic Deadweight Testers
        • Deadweight Tester Accessories
      • Manual Pressure Calibration
        • Pressure Calibrators
        • Pneumatic Pressure Control
        • Hydraulic Pressure Comparators / Pumps
      • Handheld Pressure Calibrators
      • Air Data Calibration
      • Environmental Monitors
      • Pressure Calibration Accessories
      • Pressure Calibration Custom Systems
      • Pressure Calibration Software
    • Flow Calibration
      • Gas Flow Standards
      • Gas Flow Accessories
      • GFS Primary Gravimetric Flow Standard
      • Flow Calibration Software
    • Process Calibration Tools
      • Temperature Calibrators
        • Handheld Temperature Calibrators
        • Dry-Block Calibrators and Micro-Baths
        • Precision Digital Thermometers
        • Temperature Probes
        • Infrared Calibrators
        • Hygro Thermometer with Data Logging
      • Pressure Calibrators
        • Digital Pressure Calibrators
        • Handheld Pressure Calibrators
        • Deadweight Testers
        • Precision Digital Pressure Gauges
        • Calibration Hand Pumps
      • Multifunction Calibrators
      • mA Loop Calibrators
      • Process Calibration Software
    • Calibration Software
      • MET/CAL® Software
      • MET/CAL® Support
      • Asset Management Software
      • Temperature Calibration Software
      • Pressure Calibration Software
      • Flow Calibration Software
      • Mechanical / Dimensional Calibration Software
    • Service and Support
    • All Calibration Instruments
  • Purchase Info
    • Where to Buy
    • Request a Quote
    • Request a Demo
    • Request a Sales Consultation
    • Certified Pre-Owned Equipment
    • General Services Administration (GSA)
    • Financing Program
    • National Stock Numbers (NSNs)
    • Payment Options and Tax Info
  • News
    • Press Releases
    • Promotions
    • Industry Links
    • Metrology Salary Survey
  • Training and Events
    • Conferences and Exhibitions
    • Training Courses
    • User Group Meetings
    • Web Seminars
      • Live Seminars
      • On-Demand Seminars
  • Literature and Education
    • Education Hub
    • About Calibration
    • Articles and Education
    • Product Literature
    • Product Manuals (User Guides)
    • Videos and Virtual Demos
    • Blog
  • Service and Support
    • Service Request (RMA)
    • Service Plans
    • Technical Support
    • Knowledge Base
    • Accreditations
    • Authorized Service Centers
    • Calibration Certificates
    • Community Forum
    • My MET/SUPPORT
      • Activate
      • Procedures
      • Software
      • Technical Bulletins
      • Priority Support
      • Manuals
    • Product Manuals (User Guides)
    • Safety Data Sheets (SDS)
    • Safety, Service, and Product Notices
    • Software Downloads
    • Tools
      • PT100 Calculator
      • ITS-90 Reference Function Calculator
      • Thermocouple Table Voltage Calculator
      • Thermocouple Voltage to Temperature Calculator
  • About Us
    • Contact Us
    • Visit Us
    • Employment
    • Fluke Calibration
      • Hart Scientific Temperature Calibration
      • DH Instruments Pressure and Flow Calibration
      • Pressurements Pressure Calibration
      • Ruska Pressure Calibration
    • Fluke Companies
    • Integrity and Compliance
    • Frequently Asked Questions
Home|Products|Data Acquisition and Test Equipment|Data Acquisition|2680 Series Data Acquisition Systems

Sidebar Request a Quote

Request a quote

Your information is protected by our privacy policy.

©1995-2022 Fluke Corporation
             

Secondary menu

  • Disclaimer
  • Privacy Statement
  • Terms of Use
  • Terms of Sale