7004N/7010N Nanoscan Volt Maintenance System

This product is discontinued. For a replacement please see the 734C Voltage Referrence and DC Voltage Standard.

7004N/7010N Nanoscan Volt Maintenance System
7004N/7010N Nanoscan Volt Maintenance System
Request a replacement
  • Highlights
  • Description
  • Specifications
  • Models and Accessories
  • Knowledge and Information

Nanoscan Volt Maintenance System

Fluke's 7004N and 7010N Nanoscan Volt Maintenance Systems bring all the advantages of process automation to Standards Lab Metrology. Now you can enjoy the consistency of measurement, freedom from human error, and sophisticated data reporting facilities that only an automated system can bring.

  • Ultra-Stable Statistical 10-Volt DC Voltage Reference Standard
  • Accepts between 4 and 10 Reference Modules
  • 10-Volt Average, Buffered 10-Volt Average and Average 1.018-Volt Outputs
  • Built-in Solid-State Scanner and Null Detector for Intercomparing Reference Modules or External References with 10-Volt Average
  • Automatic Intercomparisons Using Fluke's PC-based Volt Maintenance Software
  • Input for Josephson Junction Standard
  • Full Polarity Reversal Capabilities

Between 4 and 10 reference modules

Each Nanoscan system consists of one or more Model 7000 solid-state zener reference modules that plug into a mainframe chassis. The 10-Volt ouputs from these modules are routed via an analog signal backplane to the Nanoscan module where they are averaged to produce an ultra low-noise hardware Average 10 Volt output.

High sensitivity null detector

The Nanoscan module also contains a high-sensitivity (0.01ppm resolution) null detector that compares individual 10-Volt reference outputs with the Average output, enabling you to verify the stability of each reference to a very high confidence level. Individual references can also be switched in and out of the hardware average to evaluate their overall contribution.

Simple integration of external reference standards

In addition to intercomparing individual internalreferences to the system average, the null detector can also be used to measure external reference standard, providing an easy method of importing or exporting traceability from the Nanoscan system.

10-Volt Average, Buffered 10-Volt Average and Average 1.018-Volt Outputs

The Nanoscan module also generates a buffered 10V output to drive resistive loads such as Kelvin Varley dividers, and a 1.018V output for comparison with Weston cells.

Automatic intercomparison using 7050 volt maintenance software

Although the Nanoscan can be driven manually via its front panel controls, the full benefits of process automation is achieved when you use it with the 7050 Volt Maintenance Software. This software, which runs under WindowsTM95 or NT, enables you to initiate scan sequences and log all the results into an ExcelTM spreadsheet for later analysis.

10V Output
Stability
7004N:  90 days: 0.8ppm
   1 year: 1.2ppm
7010N:  90 days: 0.7ppm
   1 year: 1.0ppm
Predictability
7004N:  ±0.2 ppm/year typicalAfter 5 points, 3 mo. apart
7010N  ±0.1 ppm/year typical
   After 5 points, 3 months apart
Temperature Coefficient (15 - 35°C)
7004N:  < 0.03 ppm/°
7010N:  < 0.02 ppm/°
Noise (rms)
7004N:  0.05 to 10Hz: < 0.05 ppm RMS
   Standard deviation of 90 day regression: < 0.06 ppm
7010N:  0.01 to 10Hz: < 0.03 ppm RMS
   Standard deviation of 90 day regression: < 0.04 ppm
Hysteresis recovery
7004N:  < 0.1 ppm (after conditioning cycle and battery discharge)
7010N:  < 0.07 ppm
   (after battery discharge)
Output Resistance
   7004N/7010N: 500/n Ohm
   Where n = number of modules fitted

10V 4 wire Output (relative to Average)
Offset
   < ±1µV
Output Current
   12mA max.
Load Regulation
Zero to 2mA:  < 0.1 ppm
2mA to 12mA:  < 0.5 ppm
External Standard Input
Range:  +9.990 to +10.010V
Input Impedance:  100 Mohm + 10pF (typic

Null Detector
Range
   -9999.9 µV to +9999.9 µV
Measurement Errors
Chan. to Average:  ± 0.3% of difference
Chan.to out of Average:  ± 0.1% of difference
External Standard:  ± 0.001%
Chan. to Chan.:  ± 0.1 µV
Oven Temperature Monitor
Accuracy:  ± 3°C
Stability/Repeatability:  : ± 0.1°C/year

Battery
Type
   NiMH
Backup Period
   16 hrs from fully charged
Recharge time (typical)
   2 hours
Half Life
   5 yrs

Environment
Temperature
Operating:  +15°C to 35°C
Transit:  -18°C to 45°C
Warm-up period:  20 min to ±0.2 ppm 2 hours to final value

General Specifications
Power, battery life
7004N:  < 6W
7010N:  < 12W
12V DC Connection
   Yes
Dimensions
7004N:  133 x 449 x 355 mm
   (5.24 x 17.68 x 13.19 inch)
7010N  265 x 449 x 355 mm
   (10.43 x 17.68 x 13.19 inch)
Weight
7004N:  9.6kg (21.2Ibs)
7010N:  20kg (44.1Ibs)
Safety
   UL3111, CE marked
   EN61010-1-1:1993/A2:1995
   CETL
Model Name Description
7004N

4-Reference 'Nanoscan' Volt Maintenance System

All models include:

  • Low-Thermal Lead Set
  • Interface Cabling for a second 'Nanoscan'/'Transref' unit
  • Fibre-Optic Cabling for connection to a PC
  • 12V DC Power Supply
  • (requires at least one Model 7000 10-volt Solid State DC Voltage Reference Module)

7010N

10-Reference 'Nanoscan' Volt Maintenance System

Accessories common to all models:

Accessory Description
7004-65

Ruggedized Transit Cases for 7004N and 7004T

There are no Knowledge and Information items for this product.
  • Printer-friendly version »
  • Home
  • Products
    • New Products
    • Electrical Calibration
      • Electrical Standards
      • Electrical Calibrators
      • Bench Multimeters
      • Electrical Calibration Software
    • RF Calibration
      • RF Reference Sources
      • RF Calibration Accessories
      • RF Calibration Software
    • Data Acquisition and Test Equipment
      • Bench Multimeters
      • Data Acquisition
      • Function and Waveform Generators
      • Data Acquisition Software
    • Temperature Calibration
      • ITS-90 Temperature Standards
        • ITS-90 Fixed-point cells
        • Standard Platinum Resistance Thermometers
        • Maintenance Apparatus
        • Liquid Nitrogen Comparison Calibrator
        • Resistance Bridges
        • Standard Resistors
      • Calibration Baths
        • Compact Calibration Baths
        • Standard Calibration Baths
        • Special Application Baths
        • Bath Accessories
        • Bath Controllers
        • Bath Fluids
        • Custom Baths
      • Industrial Calibrators
        • Field Metrology Wells
        • Metrology Wells
        • Handheld Calibrators
        • Field Dry-Block Calibrators
        • Micro Baths
        • Infrared Calibrators
        • Thermocouple Furnaces
        • Dual Block Dry-Well
        • Zero-point Dry-Well
      • Probes / Sensors
        • Platinum Resistance Thermometers (PRTs)
        • Thermistors
        • Thermocouples
      • Digital Thermometer Readouts
      • Multifunction Calibrators
      • Temperature Calibration Software
    • Humidity Calibration
      • Humidity Generators
      • Humidity Data Loggers and Monitors
    • Pressure Calibration
      • Piston Gauges
        • NMI Piston Gauges
        • Absolute Piston Gauges
        • High Pressure Pneumatic Piston Gauges
        • Hydraulic Piston Gauges
        • Piston Gauge Accessories
      • Automated Pressure Controller / Calibrators
        • Low Pressure Controllers / Calibrators
        • Pneumatic Pressure Controllers / Calibrators
        • High Pressure Pneumatic Controller / Calibrators
        • Hydraulic Controller / Calibrators
      • Pressure Monitors
        • Low Pressure Monitors
        • Digital Pressure Gauges
        • Reference Pressure Monitors
      • Deadweight Testers
        • Pneumatic Deadweight Testers
        • Oil Deadweight Testers
        • Water Deadweight Testers
        • High-Pressure Hydraulic Deadweight Testers
        • Deadweight Tester Accessories
      • Manual Pressure Calibration
        • Pressure Calibrators
        • Pneumatic Pressure Control
        • Hydraulic Pressure Comparators / Pumps
      • Air Data Calibration
      • Environmental Monitors
      • Pressure Calibration Accessories
      • Pressure Calibration Custom Systems
      • Pressure Calibration Software
    • Flow Calibration
      • Gas Flow Standards
      • Gas Flow Accessories
      • GFS Primary Gravimetric Flow Standard
      • Flow Calibration Software
    • Process Calibration Tools
      • Temperature Calibrators
        • Handheld Temperature Calibrators
        • Dry-Block Calibrators and Micro-Baths
        • Precision Digital Thermometers
        • Temperature Probes
        • Infrared Calibrators
        • Hygro Thermometer with Data Logging
      • Pressure Calibrators
        • Digital Pressure Calibrators
        • Handheld Pressure Calibrators
        • Deadweight Testers
        • Precision Digital Pressure Gauges
        • Calibration Hand Pumps
      • Multifunction Calibrators
      • mA Loop Calibrators
      • Process Calibration Software
    • Calibration Software
      • MET/CAL® Software
      • MET/CAL® Support
      • Asset Management Software
      • Temperature Calibration Software
      • Pressure Calibration Software
      • Flow Calibration Software
      • Mechanical / Dimensional Calibration Software
  • Purchase Info
    • Where to Buy
    • Request a Quote
    • Request a Demo
    • Request a Sales Consultation
  • News
    • Press Releases
    • Promotions
    • Industry Links
    • Metrologist Salary Survey
  • Training and Events
    • Conferences and Exhibitions
    • Training Courses
    • Web Seminars
      • Live Seminars
      • On-Demand Seminars
  • Literature and Education
    • About Calibration
    • Articles and Education
    • Product Catalogs
    • Product Literature
    • Product Manuals (User Guides)
    • Videos and Virtual Demos
    • Blog
  • Service and Support
    • Service Request (RMA)
    • Service Plans
    • Technical Support
    • Knowledge Base
    • Accreditations
    • Authorized Service Centers
    • Calibration Certificates
    • Community Forum
    • My MET/SUPPORT
      • Activate
      • Procedures
      • Software
      • Technical Bulletins
      • Priority Support
      • Manuals
    • Product Manuals (User Guides)
    • Register Products
    • Safety Data Sheets (SDS)
    • Safety, Service, and Product Notices
    • Software Downloads
  • About Us
    • Contact Us
    • Visit Us
    • Employment
    • Fluke Calibration
      • Hart Scientific Temperature Calibration
      • DH Instruments Pressure and Flow Calibration
      • Pressurements Pressure Calibration
      • Ruska Pressure Calibration
    • Fluke Companies
    • Integrity and Compliance
    • Frequently Asked Questions
Home|Products|Obsolete Products|7004N/7010N Nanoscan Volt Maintenance System
Fluke Calibration would like your feedback

We'd like your feedback.

You can help us improve our website »

Thank you!

Questions regarding Service, General Metrology, Certificates of Calibration or if you are in need of Technical Support can be submitted via our Support Request form.

©1995-2019 Fluke Corporation
             

Secondary menu

  • Disclaimer
  • Privacy Statement
  • Webmaster
  • Terms of Use
  • Terms of Sale