908/909 Frequency References

908/909 Frequency References
Frequency References
908/909 Frequency References
Frequency References
908/909 Frequency References
Frequency References
908/909 Frequency References
Frequency References
Request a quote
  • Highlights
  • Description
  • Specifications
  • Models and Accessories
  • Knowledge and Information

Stable frequency references for test systems and calibration labs

The 908 and 909 Frequency References are ideal for use in calibration laboratories where there is a specific need to calibrate a wide range of instruments, such as frequency counters and synthesizers. Unlike off-air frequency receivers, the 908 and 909 Frequency References have excellent short-term stability that enables much faster frequency calibration.

If frequency standards are located in several departments, spread over a number of buildings, you will discover the portable 909 Rubidium Frequency Reference Standard offers a more cost-effective solution than a central reference with a costly distribution system.

  • Accurate reference "Atomic clock" in automated test systems
  • Affordable and very cost effective
  • Designed for portability with optional carrying case
  • No need for battery backup during transportation
  • Fast warm-up time

Stable frequency references for test systems and calibration labs

The 908 and 909 Frequency Reference Standards are designed for use as accurate reference clocks in automated test systems and as in-house frequency standards.

Because they require only a short warm-up time to reach specified stability, they can also be used as portable frequency standards.

The 909 Frequency Reference includes an ultra-stable Rubidium timebase ("atomic clock"), while the 908 Frequency Reference is built around a high-stability oven-controlled cut crystal oscillator. Both instruments provide five buffered 10 MHz outputs plus one 5 MHz output. Option 70 increases the number of 10 MHz outputs to ten.

Ideal for automated test (ATE) systems

Many production test systems, particularly in the telecommunications industry, require a stable external frequency clock as a reference. Depending on your needs either the 908 or the 909 can supply a stable frequency reference to up to 11 other instruments and testers, making them ideal for use in an ATE system. In addition there is a rack mounting kit available.

908 (Crystal oven)

With its high-stability oven-controlled SC-cut crystal oscillator the 908 offers the lowest purchase cost per output on the market in the 11 output version (option 70 installed).

909 (Rubidium)

The Rubidium version, with its negligible aging drift needs in practice no adjustment during the lifetime of the test system.

In-house frequency standards

Both the 908 and the 909 Frequency References are ideal for use in calibration laboratories where there is a need to calibrate a wide range of instruments, such as frequency counters and synthesizers. Unlike off-air frequency receivers, the 908 and 909 have very-high short-term stability that enables much faster frequency calibration.

Companies that require frequency standards in numerous departments spread over several buildings will find that a local Rubidium standard (909) normally offers a more cost effective solution than a central reference with a costly distribution system.

Made for portability

The 908 and 909 Frequency References are designed for portability. They perform exceptionally well as transportable fast-warm-up frequency references. Traditionally, oven oscillators using AT-cut crystal could not maintain their specification without continuous battery backup during transportation to different sites. This is because AT-cut crystals suffer from significant frequency retrace (frequency offset after a power interruption). They also need a very long warm-up time, 24 hours or more, to arrive at the final frequency value.

The 908's oven oscillator is designed around the more advanced SC-cut crystal oscillator which has virtually no retrace. In just 10 minutes the frequency is within 5x10-9 of the final value, meaning it can be in service faster. Finally, there is no need for battery back up during transportation. The warm-up of the Model Rubidium oscillator is even faster, taking only 10 minutes to reach as close as 4x10-10 from the final frequency.

For protection during transport and storage, there is a carrying case available. The 908 and 909 provide stabile, cost effective solutions for your frequency reference requirements whether in ATE, laboratory or portable applications.

Reference outputs
Base model
   5x10 MHz, 1x5 MHz: sine >0.6V rms in 50Ω
With Option 70
   10 x 10 MHz, 1 x 5 MHz: sine >0.6V rms in 50Ω
Frequency Stability
Aging per month
908 (Oven):  3x10-9
909 (Rubidium):  5x10-11
Aging per year (per 10 years)
908 (Oven):  2x10-8 (1 year)
909 (Rubidium):  1x10-9 (10 years)
Temperature
(20°C to 26°C)  
908 (Oven):  4x10-10 typ.
909 (Rubidium):  2x10-11 typ.
   --------
(0°C to +50°C)  
908 (Oven):  2.5x10-9
909 (Rubidium):  3x10--10
Short term (root Allan variance)
908 (Oven):  5x10-12, t= 10s
909 (Rubidium):  1x10-11, t=10s
   --------
908 (Oven):  5x10-12, t=1s
909 (Rubidium):  3x10-11, t=1s
Warm up (at +25oC)
908 (Oven):  10 mins. to 5x10-9
909 (Rubidium):  5.4 mins. to lock
   11 mins. to 4x10-10
Environment
Temperature
   0°C to +50°C (operating)
   -40°C to +70°C (storage)
Safety
   Compliant to EN 61010-1 and CE
EMI
   Compliant to EN 55011 ISM group, class B, EN 50082-2 and CE
Power Consumption (90-264V, 47-63 Hz)
908:
   <20W at warm up, < 7W continuous operation
909:
   <70W at warm up, <30W continuous operation
Dimensions and Weight
Size
   315 x 86 x 395 mm
   (12.4 x 3.4 x 15.5 ins)
Weight
   4.8 kg (net), 7.8 kg (shipping)
   (10.6 lb (net), 18.2 lb (shipping))
Calibration
Calibration Documentation 17025 accredited report of calibration included
Model Name Description
908

Crystal oven; 5 x 10 MHz and 1 x 5 MHz outputs

909

Rubidium; 5 x 10 MHz and 1 x 5 MHz outputs

Accessories common to all models:

Accessory Description
908-50

Rack Mount Kit

908-60

Carrying Case

908-70

Additional 5 x 10 MHz Outputs

909-50

Rack Mount Kit

909-60

Carrying Case

909-70

Additional 5 x 10 MHz Outputs

Product Manuals
application/pdf icon 908/909 Frequency Standards Operators Manual (179.8 KB)
  • Printer-friendly version »
  • Home
  • Products
    • New Products
    • Electrical Calibration
      • Electrical Standards
      • Electrical Calibrators
      • Bench Multimeters
      • Electrical Calibration Software
    • RF Calibration
      • RF Reference Sources
      • RF Calibration Accessories
      • RF Calibration Software
    • Data Acquisition and Test Equipment
      • Bench Multimeters
      • Data Acquisition
      • Function and Waveform Generators
      • Data Acquisition Software
    • Temperature Calibration
      • ITS-90 Temperature Standards
        • ITS-90 Fixed-point cells
        • Standard Platinum Resistance Thermometers
        • Maintenance Apparatus
        • Liquid Nitrogen Comparison Calibrator
        • Resistance Bridges
        • Standard Resistors
      • Calibration Baths
        • Compact Calibration Baths
        • Standard Calibration Baths
        • Special Application Baths
        • Bath Accessories
        • Bath Controllers
        • Bath Fluids
        • Custom Baths
      • Industrial Calibrators
        • Field Metrology Wells
        • Metrology Wells
        • Handheld Calibrators
        • Field Dry-Block Calibrators
        • Micro Baths
        • Infrared Calibrators
        • Thermocouple Furnaces
        • Dual Block Dry-Well
        • Zero-point Dry-Well
      • Probes / Sensors
        • Platinum Resistance Thermometers (PRTs)
        • Thermistors
        • Thermocouples
      • Digital Thermometer Readouts
      • Multifunction Calibrators
      • Temperature Calibration Software
    • Humidity Calibration
      • Humidity Generators
      • Humidity Data Loggers and Monitors
    • Pressure Calibration
      • Piston Gauges
        • NMI Piston Gauges
        • Absolute Piston Gauges
        • High Pressure Pneumatic Piston Gauges
        • Hydraulic Piston Gauges
        • Piston Gauge Accessories
      • Automated Pressure Controller / Calibrators
        • Low Pressure Controllers / Calibrators
        • Pneumatic Pressure Controllers / Calibrators
        • High Pressure Pneumatic Controller / Calibrators
        • Hydraulic Controller / Calibrators
      • Pressure Monitors
        • Low Pressure Monitors
        • Digital Pressure Gauges
        • Reference Pressure Monitors
      • Deadweight Testers
        • Pneumatic Deadweight Testers
        • Oil Deadweight Testers
        • Water Deadweight Testers
        • High-Pressure Hydraulic Deadweight Testers
        • Deadweight Tester Accessories
      • Manual Pressure Calibration
        • Pressure Calibrators
        • Pneumatic Pressure Control
        • Hydraulic Pressure Comparators / Pumps
      • Handheld Pressure Calibrators
      • Air Data Calibration
      • Environmental Monitors
      • Pressure Calibration Accessories
      • Pressure Calibration Custom Systems
      • Pressure Calibration Software
    • Flow Calibration
      • Gas Flow Standards
      • Gas Flow Accessories
      • GFS Primary Gravimetric Flow Standard
      • Flow Calibration Software
    • Process Calibration Tools
      • Temperature Calibrators
        • Handheld Temperature Calibrators
        • Dry-Block Calibrators and Micro-Baths
        • Precision Digital Thermometers
        • Temperature Probes
        • Infrared Calibrators
        • Hygro Thermometer with Data Logging
      • Pressure Calibrators
        • Digital Pressure Calibrators
        • Handheld Pressure Calibrators
        • Deadweight Testers
        • Precision Digital Pressure Gauges
        • Calibration Hand Pumps
      • Multifunction Calibrators
      • mA Loop Calibrators
      • Process Calibration Software
    • Calibration Software
      • MET/CAL® Software
      • MET/CAL® Support
      • Asset Management Software
      • Temperature Calibration Software
      • Pressure Calibration Software
      • Flow Calibration Software
      • Mechanical / Dimensional Calibration Software
    • Service and Support
    • All Calibration Instruments
  • Purchase Info
    • Where to Buy
    • Request a Quote
    • Request a Demo
    • Request a Sales Consultation
    • Certified Pre-Owned Equipment
    • General Services Administration (GSA)
    • Financing Program
    • National Stock Numbers (NSNs)
    • Payment Options and Tax Info
  • News
    • Press Releases
    • Promotions
    • Industry Links
    • Metrology Salary Survey
  • Training and Events
    • Conferences and Exhibitions
    • Training Courses
    • User Group Meetings
    • Web Seminars
      • Live Seminars
      • On-Demand Seminars
  • Literature and Education
    • Education Hub
    • About Calibration
    • Articles and Education
    • Product Literature
    • Product Manuals (User Guides)
    • Videos and Virtual Demos
    • Blog
  • Service and Support
    • Service Request (RMA)
    • Service Plans
    • Technical Support
    • Knowledge Base
    • Accreditations
    • Authorized Service Centers
    • Calibration Certificates
    • Community Forum
    • My MET/SUPPORT
      • Activate
      • Procedures
      • Software
      • Technical Bulletins
      • Priority Support
      • Manuals
    • Product Manuals (User Guides)
    • Register Products
    • Safety Data Sheets (SDS)
    • Safety, Service, and Product Notices
    • Software Downloads
    • Tools
      • ITS-90 Reference Function Calculator
      • Thermocouple Table Voltage Calculator
      • Thermocouple Voltage to Temperature Calculator
  • About Us
    • Contact Us
    • Visit Us
    • Employment
    • Fluke Calibration
      • Hart Scientific Temperature Calibration
      • DH Instruments Pressure and Flow Calibration
      • Pressurements Pressure Calibration
      • Ruska Pressure Calibration
    • Fluke Companies
    • Integrity and Compliance
    • Frequently Asked Questions
Home|Products|Electrical Calibration|Electrical Standards|908/909 Frequency References

Sidebar Request a Quote

Request a quote

Your information is protected by our privacy policy.

Fluke Calibration would like your feedback

We'd like your feedback.

You can help us improve our website »

Thank you!

If you purchased an item from a Fluke authorized distributor, please contact them directly with questions regarding Certificates of Calibration or other documentation.

Support requests for items purchased from, or serviced directly by Fluke and general Metrology questions can be submitted via our online Support Request form and a Fluke representative will be in contact with you.

©1995-2021 Fluke Corporation
             

Secondary menu

  • Disclaimer
  • Privacy Statement
  • Webmaster
  • Terms of Use
  • Terms of Sale